CNNC 22 · Project 594
Carport solar + storage retrofit: 135 kWp PV + 232 kWh storage.
Longsun · Dubai, UAE · DET licence 1628064
Integrated solar and storage EPC, plus Energy Pods, portable power and other new-energy products, with energy solutions sized to the load at factories, warehouses, mines, labour camps, site offices and building sites across the UAE.
Project referencesCSCEC Middle EastCNNC Project 594JBD Sharjah Free ZoneWhite Rock MineralsAl Baraa Group
A gable roof extends out on both sides for looks and shade. It carries ten 640 W monocrystalline modules, 6.4 kWp in all, and the structure is designed for the module load and for the crews who install and maintain them.
Based on PVGIS satellite irradiance data for the Middle East, and allowing for heat, system losses and dust, the 6.4 kWp roof system is expected to generate about 9,700 kWh a year for lighting, office equipment, air-conditioning and other site loads.
The energy management system (EMS) uses solar first and stores the surplus in the battery; only when solar and storage fall short does it start the generator.
A 6 × 3.6 m cabin with the inverter, 15 kWh of storage, water recycling and a separate washroom built in, ready for site office work and power.
LiFePO₄ batteries store the daytime surplus and supply power when solar falls short. Capacity is sized to the actual load.
Handwash water is filtered, disinfected and reused, and the separate washroom uses a waterless microbial system, so the pod relies less on external water and sewer connections.
75 mm three-layer fire-resistant insulated panels suit site conditions. When the project ends, the whole pod moves on to the next site.
08 — CORE SPECS
Main configuration below; contact us for the full specification.
Energy Pod · capacity
The roof comes with 6.4 kWp of PV and 15 kWh of storage as standard. With the carport, PV goes up to 12.8 kWp; storage can be set from 5 to 15 kWh.
Drag the sliders to see the configuration and expected yield.
Modules drawn at 1134 × 2380 mm and 640 W. Generation from PVGIS data for Dubai (estimated as flat-mounted, less 5% for dust); usable energy at 90% depth of discharge. Final layout, pitch, overhang and wind design are confirmed per project.
Energy Pod · where it goes
Roof solar and storage built into the site office run the lights, computers and air-conditioning, cutting reliance on diesel power.
PV and storage are sized to the accommodation's AC, lighting and usage hours to cover the evening and night; a backup generator fills any gap.
02 · Solar + Storage EPC
We build solar and storage systems sized to the site on factory and warehouse roofs, carports and open ground, with one team from survey and design through installation, commissioning and O&M.
Example: a 1 MWp project in Dubai on assumed tariffs and yield: about 1,665 kWh per kWp a year (PVGIS); grid power at the DEWA commercial rate of about AED 0.44/kWh including the fuel surcharge; diesel at about AED 2/kWh fuel cost, with all generation used on site. Actual savings depend on self-consumption, load, losses and running costs.
Twelve months of O&M are included after commissioning.
Solar + Storage EPC · diesel cost
Solar carries the daytime load and storage covers the night, so the generator runs less and burns less fuel.
UAE retail diesel price per litre for October 2026, revised monthly; a year earlier it was AED 2.71.
Fuel cost of one kWh from a site generator (about 1.6 at full load, 3.0 at light night loads). Generator hire, servicing and labour are extra, so diesel power costs more in total.
DEWA commercial tariff for grid-tied comparison (about 38 fils plus a fuel surcharge of about 6 fils).
1 UAE Fuel Price Committee, via Khaleej Times. 2 AGG P22D5 / Perkins 404A-22G1 datasheet, 0.33–0.63 L/kWh × AED 4.80. 3 DEWA commercial tariff and fuel surcharge.
Solar + Storage EPC · how power flows
Solar supplies the load first and stores the surplus; when solar falls short, storage takes over, and the backup generator starts only when needed.
Shown: an off-grid or hybrid system with a backup generator. Grid-tied projects may not need one.
PV first · surplus to storage · storage at night · backup generator only when needed
Solar + Storage EPC · where it goes
Grid-tied PV or solar + storage, matched to your usage hours and roof, lowers grid or diesel power spend.
PV, storage and a backup generator for mines, crushers and remote sites cut fuel use and fuel deliveries.
Solar + Storage EPC · reference loads
Initial estimates only; actual use depends on equipment power, numbers and running hours.
| Load | Summer | Winter | Basis |
|---|---|---|---|
| Power-tool userkWh per worker per 10 h shift | 2.5 | 2.5 | Grinders, rotary hammers and saws draw 1–2 kW and run about 15–25% of a shift. |
| Site office cabinkWh a day per 18–22 m² cabin, day use | 28 | 10 | 2-ton split AC (Gulf sizing of 90–100 BTU per sq ft), 4–6 PCs, lighting, kettle and fridge. |
| LED floodlightkWh a day per 150 W fitting, 11 h a night | 1.65 | 1.65 | Night work or security lighting. |
| Always-on equipmentkWh a day: CCTV, Wi-Fi, gates at 0.3–1 kW around the clock | 7–24 | 7–24 | A common load that still needs power at night. |
Diesel per kWh. A 20 kVA set burns about 0.33 L per kWh at full load and 0.6 L or more at the light loads typical of night-time (AGG P22D5 / Perkins 404A-22G1 datasheet: 2.9, 4.0 and 5.3 L/h at 50, 75 and 100% load).
These are estimates. Cooling is modelled for 40–46 °C summer days and typical cabin insulation. At survey we replace them with your generator logs, fuel receipts and equipment list.
Solar + storage EPC · sizing calculator
Enter the site's average load and daily working hours to see the expected energy use and a PV and storage size. Results are for initial sizing only.
Energy use is the average load times the working hours. PV is sized from irradiance data and storage from the energy needed outside solar hours. Results are for initial sizing; the real system depends on the site, season, equipment power and backup requirements.
Project references
Carport solar + storage retrofit: 135 kWp PV + 232 kWh storage.
3 PV modules + a 5 kWh portable power unit for stand-alone power at small sites.
Factory rooftop PV cutting diesel power spend, ready for later expansion.
Rooftop PV pilot at a steel pipe plant, with a 100 kW system planned next.
Ground-mount PV at a mining site: 700 kW PV + 2 MWh storage.
Labour camp rooftop PV, 200 kW.
Labour camp solar + storage: 150 kW PV + 464 kWh storage.
Food plant solar + storage: 281 kWp PV + 445 kWh storage.
Grid-tied PV for a food plant, 227 kWp.
Grid-tied PV for a steel and cement plant, 306 kWp.
The listed projects, at different stages, add up to about 2.0 MW of solar and 3.1 MWh of storage.
03 · Portable power · SS series
Light and portable, for lighting and small devices.
Example: a 60 W LED work light for about 14 hours (at about 85% usable energy).
For common power tools and site work.
Example: about 2 hours of full-load use on a 1.2 kW rotary hammer (at about 85% usable energy).
For high-power tools and air-conditioning.
Example: about 2.8 hours on a 1.5 kW grinder, or about 3.9 hours on a 1.1 kW air-conditioner (at about 85% usable energy).
More capacity for longer use.
Example: a 2 kW load for about 3 hours (at about 85% usable energy).
Charge at an Energy Pod or site solar hub, then take the power to floors, roofs and other work points, with fewer long cable runs.
Portable power · temporary site power
For floors, roofs and scattered work points that temporary power has not reached. Capacity and numbers are set by tool power, how often tools run and how long the work lasts.
Credentials
Our headquarters has delivered commercial and industrial rooftop PV, distributed solar and storage projects for factories, industrial parks, commercial buildings and mines in China. Longsun brings that design, installation and project-management capability to the UAE.
Available at each project stage:
Questions engineers ask
Yes, it can be configured for AC. Whether it covers a full day depends on the AC's power, hours of use, insulation and the solar and storage capacity. We size it to the actual load and add carport PV or a backup source where needed.
Off-grid projects can keep a generator as backup, depending on the load and how reliable the supply must be. The system uses solar and storage first, so the generator runs less.
Equipment is chosen for its operating temperature and protection rating, with ventilation, shading and regular module cleaning. Portable units must be kept out of rain and water; follow the product manual.
Water recycling and a waterless washroom reduce the need for external connections. Top-up, cleaning and servicing depend on the configuration and the number of users.
We confirm the load, usage hours and site conditions, then size the PV, storage and backup power, and send a technical proposal and quotation.
We are based in Dubai and serve all emirates of the UAE. Contact us to confirm a specific project.
Yes. We survey the site, review your power needs and return an initial proposal and quotation.
Next step
Send site photos, an equipment list, a power bill or diesel records, and we will arrange a survey and come back with a configuration and quotation.